Tag: kg

islands incinerators

Application : four islands in Croatia Capacity/island : 4000 kg/day ; 25000 kg/day ; 31000 kg/day ; 48000 kg/day Burning temperature – over 12000C Two chambers – minimum Emissions – dioxin and heavy metaly – better then Kyoto protocol Emission – monitoring system Waste unloiding – directly from waste track to incinerator Burn Rate(Average kgs/hr)  25 kg   primary chamber  800 degree   secondary chamber  1000 degree   chimney  standard   shredder

Continue reading

islands incinerators

Application : four islands in Croatia Capacity/island : 4000 kg/day ; 25000 kg/day ; 31000 kg/day ; 48000 kg/day Burning temperature – over 12000C Two chambers – minimum Emissions – dioxin and heavy metaly – better then Kyoto protocol Emission – monitoring system Waste unloiding – directly from waste track to incinerator Burn Rate(Average kgs/hr)  25 kg   primary chamber  800 degree   secondary chamber  1000 degree   chimney  standard   shredder

Continue reading

Pig corpses / stray dogs and larger animal carcasses

Pig corpses / stray dogs and larger animal carcasses – Load capacity in the range of up to 300 kg / Burn rate approx. 50 kg per hour Temperature Controlled Burner. Incinerators to be designed to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, reliable, economical Incinerator with relevant control, easy to operate and self-contained. Units to be pre-assembled, pre-piped, pre-wired & tested before Transport / Export The supply will comprise the special equipment for effective medical / clinical waste management as mentioned above for a new private environment management company with operations in West and East Malaysia; Indonesia and Thailand to carry out those professional services in order to comply with the safe disposal requirements for clinical and medical waste in the region and to meet the higher technical standard in this particular field. 1.Burning rate: 250 Kg/hr.  2.It should be able to Operate not Less than 10 hours/day 3.This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…  4.Design Specification: Types A, B, C, D, and E of medical waste 5.“PYROLYTIC” combustion, by controlling the gasification of waste.  6.The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings. 7.It should be able to reduce the volume of wastes by 98%. 8.It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.  The incineration should be completely free from visible smoke as well as offensive odours.  9. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg  The Temperatures of combustion: Minimum will be 850oC and max 1400oC Post combustion: >1100oC. 10. The Internal diameter of the Chimney: Ø 400mm² and its height: 8 Meter   11. The Volume of the combustion chamber: Not Less Than 2.3 M³  12. Burner operation should be Automatic On/Off 13. Fuel : diesel, LPG, Natural Gas, Bio fuel

Continue reading

Pig corpses / stray dogs and larger animal carcasses

Pig corpses / stray dogs and larger animal carcasses – Load capacity in the range of up to 300 kg / Burn rate approx. 50 kg per hour Temperature Controlled Burner. Incinerators to be designed to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, reliable, economical Incinerator with relevant control, easy to operate and self-contained. Units to be pre-assembled, pre-piped, pre-wired & tested before Transport / Export The supply will comprise the special equipment for effective medical / clinical waste management as mentioned above for a new private environment management company with operations in West and East Malaysia; Indonesia and Thailand to carry out those professional services in order to comply with the safe disposal requirements for clinical and medical waste in the region and to meet the higher technical standard in this particular field. 1.Burning rate: 250 Kg/hr.  2.It should be able to Operate not Less than 10 hours/day 3.This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…  4.Design Specification: Types A, B, C, D, and E of medical waste 5.“PYROLYTIC” combustion, by controlling the gasification of waste.  6.The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings. 7.It should be able to reduce the volume of wastes by 98%. 8.It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.  The incineration should be completely free from visible smoke as well as offensive odours.  9. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg  The Temperatures of combustion: Minimum will be 850oC and max 1400oC Post combustion: >1100oC. 10. The Internal diameter of the Chimney: Ø 400mm² and its height: 8 Meter   11. The Volume of the combustion chamber: Not Less Than 2.3 M³  12. Burner operation should be Automatic On/Off 13. Fuel : diesel, LPG, Natural Gas, Bio fuel

Continue reading

Design standard Multiple chamber incinerator

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance

Continue reading

Design standard Multiple chamber incinerator

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance

Continue reading

Incinerator Rated Capacity: 100/KG/Hr

Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements  Primary Combustion Chamber  Waste Charging Door: Provided with refractory lining with sealing gaskets  Ash Removed Door: Provided with refractory lining with sealing gaskets  Outer Body MOC: Mild Steel, 5mm  Primary Chamber: Stainless Steel  Operating Temperature :800. ± 50◦C  Insulation: Insulation Brick  Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load )  Electrical Supply :3 Phase 440 Volt  Control Panel  MOC: Mild Steel Power Coated No. of Temp: Controllers : 2 Nos  Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase. I.D.Fan Type: Centrifugal Type  MOC: Mild Steel

Continue reading

Incinerator Rated Capacity: 100/KG/Hr

Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements  Primary Combustion Chamber  Waste Charging Door: Provided with refractory lining with sealing gaskets  Ash Removed Door: Provided with refractory lining with sealing gaskets  Outer Body MOC: Mild Steel, 5mm  Primary Chamber: Stainless Steel  Operating Temperature :800. ± 50◦C  Insulation: Insulation Brick  Heating Elements Type: Kanthal Al Grade Power Consumption: 75 KW ( Initial Load )  Electrical Supply :3 Phase 440 Volt  Control Panel  MOC: Mild Steel Power Coated No. of Temp: Controllers : 2 Nos  Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase. I.D.Fan Type: Centrifugal Type  MOC: Mild Steel

Continue reading

Refractory constructions incinerator

* Burning Rate                                                     (50-120kg/hour) * Minimum Operating Temperature                (850°ϲ(Primary combustion) * Maximum Operating Temperature               (1450°ϲ(Afterburner chamber) * Secondary Burning Capacity                         (Compulsory) * Density Insulation                                           (20mm high) * Refractory Casting                                          (Minimum 65mm) * Heavy duty refracting lining to withstand    (1500°ϲ) * Average burn out time: Maximum                (3.0 hours) * Fuel Type                                                          (Diesel) * Fuel Consumption in L/hr:                            (7.5 to 9) * Residence time in secondary chamber     (2 sec.) * Residue ash post 100kg                               (Max. 3.8kg) * Installation period                                            (Maximum 7days) Type : Refractory constructions Steel Structure 400+ Silica board + Fire Brick and Castable between Size : Outside – W 740 x L 1112 x H 790 / Inside – W 400 x L 800 x H 560 (mm) Fire load of Combustion volume : 0.18 m3 Fire table area : 0.32 m2 Material : SS400 x 6.0T, Silica Board, Fire Brick (SK-36), Castable (HACT-160)

Continue reading

محرقة

وصف المنتج استجابة التكنولوجيا (الأسئلة الشائعة) س: ما نوع النفايات التي يمكن استخدامها في هذا الجهاز؟ ج: هذه المعدات للنفايات

Continue reading